Cask Report
General
TN 106
ORANO Nuclear Packages and Services(NPS)
Transport of materials irradiated or non-irradiated and sources
- Type B(U)/B(U)F or B(M)/B(M)F CSI:0
- Fissile/Non fissile-fissile excepted:
• Rods/pins/segments of uranium oxide and / or mixed uranium and plutonium oxide non irradiated :
- or irradiated in PWR/BWR
- or re-irradiated in an experimental reactor
- or irradiated in FNR (with presence of sodium)
• Rods/pins/segments/plate of uranium materials irradiated in RR, UNGG or PHWR
Non fissile-fissile excepted:
• Rods/pins/segments of americium oxide and / or mixed oxide of plutonium and americium and / or Uranium oxide non irradiated or irradiated in FNR with presence of Neptunium-237
Loads depending on the burnup, enrichment in 235U (up to 10 % for uranium oxides and 37 % uranium materials), concentration of Pu (MOX) and the cooling period.
A specific extension feasibility study could be performed if the content is different from the description above. In this case, please contact us.
- • Certificate: F/379/B(U)F-96 valid until September 30th, 2022
• Certificate: F/379/B(U)-96 valid until September 30th, 2022
• Past validations: Germany, Switzerland, Denmark, Sweden, Norway, USA
• Current validation: Belgium
- • Different possible internal arrangements such as baskets, racks, capsules
• Auxiliary transport equipment: transport frame, handling lifting beam, IP1 toolbox, ISO 20’ open top transport containers etc.
• Overall size with shock absorbers:
- Diameter : 1 458 mm
- Length: 3 624 - 3 824 mm
- Gross mass: 11 620 – 12 300 kg
• Overall size without shock absorbers:
- Diameter : 958 mm
- Length: 2 978 - 3 178 mm
• Cavity size:
- Diameter : 203 mm
- Length: 2 200 - 2 400 mm
• Maximal weight of the content : 254 kg/meter cavity (including the internal arrangements)
• Maximal power for the whole package: 100 W
• Fissile or Non-fissile material
- • The TN 106 is equipped with a rotating plug to accommodate the connection on the hot cell wall for loading or unloading in secure and safe conditions
• 2 units available with 2 different useful cavity lengths (2.200 to 2.400 mm)
- • Road
• Rail
• Sea
- • Vertical and horizontal
• Dry or wet (possible) loading or unloading
Yes
• France (CEA) – Switzerland (PSI) – UK (Sellafield)
• Belgium (SCK-CEN Mol) – Sweden (Studsvik Nuclear)
Orano NPS
1 rue des Hérons – 78180 Montigny-le-Bretonneux - France
orano-tn.sales@orano.group - +33 (0) 1 34 96 50 00
chrsty.alistan@orano.group - +33 (0) 6 89 70 57 66